A failed chimney, fixed in three stages

Send your repair list

How the stages are built

A Level 2 that turns up eight problems can feel like an all or nothing bill. It rarely is. We sort the list by what each item does if it is left alone: anything that can let smoke, heat or fire reach the house goes into stage one; anything that lets water into the masonry goes into stage two; anything that only makes the fireplace burn better goes into stage three.

The order matters for clean burning as much as for safety. A flue with gaps leaks smoke into walls and attic space, and an uncovered chimney top takes in rain that soaks the brick and loosens deposits. Fixing those first means the fireplace is safe to light while you plan the rest.

  • Stage one: flue cracks, open tile joints, a missing cap, a damaged firebox
  • Stage two: crown cracks, leaking flashing, a cricket behind a wide chimney
  • Stage three: an insert, a top sealing damper or other upgrades

What can wait

Stage two items can usually wait for drier weather, but not through winter after winter, because water damage spreads with each storm. Stage three items can wait as long as you like. Each line on the plan says whether the fireplace can be used before that item is done.

If a stage one item is open, we tell you not to light the fireplace until it is fixed. That is the one piece of advice we will not soften.

Prices by stage

Wherever our price list covers an item, the plan uses that figure, and the table below shows the ones that come up most. A cap is different. It is quoted on site, and the flue size and the material set its price.

Items without a published price, such as relining, a crown rebuild or a damper, carry their own figure on the written scope. You can approve one stage at a time and come back to the next when you are ready.

Prices that often appear in a staged plan

These items turn up again and again on failed inspections. The cap is quoted after we measure. Anything not listed here gets its own line on the written scope.

Camera survey the plan is built on
$400
Water entry found and sealed
$575 to $3,450
Roof diverter on the uphill side
$460 to $1,040
Diverter plus a new set of flashing
$690 to $1,700
Gas insert and liner, a stage three upgrade
$2,850 to $5,750
Cap fitted over the flue
Quoted after we measure

Staged repair questions

Is the fireplace safe to use between stages?

Once stage one is finished, usually yes. Before that, no. The plan states it item by item so nobody has to guess.

Can a later stage be done by another company?

Yes. The scope is yours to use. Whoever does a flue repair, we suggest having the flue looked at on camera afterward.

Do stages cost more than doing everything at once?

Sometimes a little, because roof setup happens more than once. Where two items share a setup, such as a crown and a cap, we put them in the same stage so you pay for it once.

Does code require every item on the list?

The smoke and fire items are what NFPA 211 and the building code care about most. Stage three items are choices, and the plan labels them that way.

What if the inspection came from another company?

Send us the findings. We may need our own look at the flue to price the work, and if so we tell you before anything is booked.

A long repair list does not have to be one bill

Send the findings through our contact page and we will sort them into stages, with a price or a written scope for each one.

Call (562) 449-0245
Call (562) 449-0245